new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Mar 12

LMUFormer: Low Complexity Yet Powerful Spiking Model With Legendre Memory Units

Transformer models have demonstrated high accuracy in numerous applications but have high complexity and lack sequential processing capability making them ill-suited for many streaming applications at the edge where devices are heavily resource-constrained. Thus motivated, many researchers have proposed reformulating the transformer models as RNN modules which modify the self-attention computation with explicit states. However, these approaches often incur significant performance degradation. The ultimate goal is to develop a model that has the following properties: parallel training, streaming and low-cost inference, and SOTA performance. In this paper, we propose a new direction to achieve this goal. We show how architectural modifications to a recurrent model can help push its performance toward Transformer models while retaining its sequential processing capability. Specifically, inspired by the recent success of Legendre Memory Units (LMU) in sequence learning tasks, we propose LMUFormer, which augments the LMU with convolutional patch embedding and convolutional channel mixer. Moreover, we present a spiking version of this architecture, which introduces the benefit of states within the patch embedding and channel mixer modules while simultaneously reducing the computing complexity. We evaluated our architectures on multiple sequence datasets. In comparison to SOTA transformer-based models within the ANN domain on the SCv2 dataset, our LMUFormer demonstrates comparable performance while necessitating a remarkable 53 times reduction in parameters and a substantial 65 times decrement in FLOPs. Additionally, owing to our model's proficiency in real-time data processing, we can achieve a 32.03% reduction in sequence length, all while incurring an inconsequential decline in performance. Our code is publicly available at https://github.com/zeyuliu1037/LMUFormer.git.

  • 4 authors
·
Jan 19, 2024

Prediction of the Position of External Markers Using a Recurrent Neural Network Trained With Unbiased Online Recurrent Optimization for Safe Lung Cancer Radiotherapy

During lung radiotherapy, the position of infrared reflective objects on the chest can be recorded to estimate the tumor location. However, radiotherapy systems have a latency inherent to robot control limitations that impedes the radiation delivery precision. Prediction with online learning of recurrent neural networks (RNN) allows for adaptation to non-stationary respiratory signals, but classical methods such as RTRL and truncated BPTT are respectively slow and biased. This study investigates the capabilities of unbiased online recurrent optimization (UORO) to forecast respiratory motion and enhance safety in lung radiotherapy. We used 9 observation records of the 3D position of 3 external markers on the chest and abdomen of healthy individuals breathing during intervals from 73s to 222s. The sampling frequency was 10Hz, and the amplitudes of the recorded trajectories range from 6mm to 40mm in the superior-inferior direction. We forecast the 3D location of each marker simultaneously with a horizon value between 0.1s and 2.0s, using an RNN trained with UORO. We compare its performance with an RNN trained with RTRL, LMS, and offline linear regression. We provide closed-form expressions for quantities involved in the loss gradient calculation in UORO, thereby making its implementation efficient. Training and cross-validation were performed during the first minute of each sequence. On average over the horizon values considered and the 9 sequences, UORO achieves the lowest root-mean-square (RMS) error and maximum error among the compared algorithms. These errors are respectively equal to 1.3mm and 8.8mm, and the prediction time per time step was lower than 2.8ms (Dell Intel core i9-9900K 3.60 GHz). Linear regression has the lowest RMS error for the horizon values 0.1s and 0.2s, followed by LMS for horizon values between 0.3s and 0.5s, and UORO for horizon values greater than 0.6s.

  • 5 authors
·
Jun 2, 2021

Prediction of the motion of chest internal points using a recurrent neural network trained with real-time recurrent learning for latency compensation in lung cancer radiotherapy

During the radiotherapy treatment of patients with lung cancer, the radiation delivered to healthy tissue around the tumor needs to be minimized, which is difficult because of respiratory motion and the latency of linear accelerator systems. In the proposed study, we first use the Lucas-Kanade pyramidal optical flow algorithm to perform deformable image registration of chest computed tomography scan images of four patients with lung cancer. We then track three internal points close to the lung tumor based on the previously computed deformation field and predict their position with a recurrent neural network (RNN) trained using real-time recurrent learning (RTRL) and gradient clipping. The breathing data is quite regular, sampled at approximately 2.5Hz, and includes artificial drift in the spine direction. The amplitude of the motion of the tracked points ranged from 12.0mm to 22.7mm. Finally, we propose a simple method for recovering and predicting 3D tumor images from the tracked points and the initial tumor image based on a linear correspondence model and Nadaraya-Watson non-linear regression. The root-mean-square error, maximum error, and jitter corresponding to the RNN prediction on the test set were smaller than the same performance measures obtained with linear prediction and least mean squares (LMS). In particular, the maximum prediction error associated with the RNN, equal to 1.51mm, is respectively 16.1% and 5.0% lower than the maximum error associated with linear prediction and LMS. The average prediction time per time step with RTRL is equal to 119ms, which is less than the 400ms marker position sampling time. The tumor position in the predicted images appears visually correct, which is confirmed by the high mean cross-correlation between the original and predicted images, equal to 0.955.

  • 4 authors
·
Jul 13, 2022